Products

Featured products

  • Diffractometer
    Diffractometer
    1. The accuracy of Diffractometer is high. 2. The application range of Diffractometer is wide. 3. Diffractometer is easy to operate, convenient and efficient.
    More
  • Single Crystal XRD
    Single Crystal XRD
    1.The single crystal machine adopts PLC control technology. 2.Modular design, accessories plug and play. 3.Electronic lead door interlocking equipment with double protection. 4.Single crystal X-ray tube: a variety of targets can be selected, such as Cu, Mo,etc. 5. Single crystal adopts four-circle concentric technology to ensure that the center of no goniometer remains unchanged.
    More
  • A 2D X-ray Diffractometer
    A 2D X-ray Diffractometer
    Advantages: Continuously adjustable X-ray penetration depth Capability to observe the distribution of crystal planes with different orientations Analysis of orientation distribution in samples such as fibers, thin films, and powders Examination of structural characteristics like lattice distortion and crystallite size
    More
  • X-ray Diffraction Residual Stress Analyzer
    X-ray Diffraction Residual Stress Analyzer
    TD-RSD XRD Residual Stress Analyzer ±7MPa accuracy, dual-detector innovation, full-auto operation & powerful software. Optimize processes, enhance product reliability. Compact, efficient, leading solution.
    More

Contact us

Grazing incident X-ray diffraction

2024-01-13

Grazing incidence means that the X-ray is exposed to the film at a very small incidence Angle (< 5°), which greatly reduces the penetration depth in the film. At the same time, the larger low incidence Angle increases the X-ray irradiation area on the sample and increases the volume of the sample participating in the diffraction. The role of GID in the structure analysis of thin films is introduced in this paper.


Example: Single-layer film GID test

In this example, the sample is a 14nm RuO2 polycrystalline film prepared on a (100) monocrystalline silicon substrate. Therefore, the signal of the thin film sample in the conventional XRD pattern is masked by the signal of the Si single crystal. Although the diffraction peaks of the thin film can be seen in the enlarged image, the signal is very weak. The GID spectrum of the sample at an incident Angle of 0.3 degrees is shown in Figure 2. There is no signal of Si single crystal substrate in the figure, and the film signal is obvious. 

X-ray

                                                                                    Fig1

XRD

                                                                                    Fig2



Get the latest price? We will reply as soon as possible (within 12 hours)

top