Products

Featured products

  • Diffractometer
    Diffractometer
    1. The accuracy of Diffractometer is high. 2. The application range of Diffractometer is wide. 3. Diffractometer is easy to operate, convenient and efficient.
    More
  • Single Crystal XRD
    Single Crystal XRD
    1.The single crystal machine adopts PLC control technology. 2.Modular design, accessories plug and play. 3.Electronic lead door interlocking equipment with double protection. 4.Single crystal X-ray tube: a variety of targets can be selected, such as Cu, Mo,etc. 5. Single crystal adopts four-circle concentric technology to ensure that the center of no goniometer remains unchanged.
    More
  • Series X-ray Crystal Analyzer
    Series X-ray Crystal Analyzer
    1. X-ray instrument is easy to operate and fast to detect. 2. X-ray instrument is accurate and reliable, with excellent performance. 3. X-ray instrument has various functional accessories to meet the needs of different testing purposes.
    More
  • Powder Diffractometer
    Powder Diffractometer
    1. Detector type: Array detector or SDD detector; 2. PLC automatic control calculus, Integration mode conversion, PLC automatically performs PHA, dead time correction 3.Sample measurement type: powder sample, liquid samples, melt-state samples, viscous samples, loose powders, bulk solid samples 4.Available with a variety of diffractometer accessories 5.Maximum output powder: 3kW
    More

Contact us

Powerful analysis software for diffraction instruments

2024-09-27

Software feature description:

This program is a self-developed program. It contains various quantitative methods developed independently, in accordance with diffraction theory, and calculated entirely using integrated intensity.Analysis function. If this program contains the function of full spectrum peak fitting, separation and quantification that can still be accurately quantified under different phase line widths; as

The function of the integrated intensity quantification method, which can conveniently automatically eliminate the interference of overlapping peaks of this phase and other phases, and is not affected by the different line widths of each phase, such as

Complete PDF file calculation spectrum combination full spectrum fitting method, custom card file calculation spectrum combination full spectrum fitting method, etc. All the above methods use integration.

The concept of intensity can be quantified by full spectrum fitting without involving structure and with different phase line widths. Can exclude overlapping peaks.Interference can reduce or eliminate the influence of preferred orientation.


Get the latest price? We will reply as soon as possible (within 12 hours)

top