Products

Featured products

  • Diffractometer
    Diffractometer
    1. The accuracy of Diffractometer is high. 2. The application range of Diffractometer is wide. 3. Diffractometer is easy to operate, convenient and efficient.
    More
  • Single Crystal XRD
    Single Crystal XRD
    1.The single crystal machine adopts PLC control technology. 2.Modular design, accessories plug and play. 3.Electronic lead door interlocking equipment with double protection. 4.Single crystal X-ray tube: a variety of targets can be selected, such as Cu, Mo,etc. 5. Single crystal adopts four-circle concentric technology to ensure that the center of no goniometer remains unchanged.
    More
  • Series X-ray Crystal Analyzer
    Series X-ray Crystal Analyzer
    1. X-ray instrument is easy to operate and fast to detect. 2. X-ray instrument is accurate and reliable, with excellent performance. 3. X-ray instrument has various functional accessories to meet the needs of different testing purposes.
    More
  • Powder Diffractometer
    Powder Diffractometer
    1. Detector type: Array detector or SDD detector; 2. PLC automatic control calculus, Integration mode conversion, PLC automatically performs PHA, dead time correction 3.Sample measurement type: powder sample, liquid samples, melt-state samples, viscous samples, loose powders, bulk solid samples 4.Available with a variety of diffractometer accessories 5.Maximum output powder: 3kW
    More

Contact us

X-ray Absorption Fine Structure

2024-03-18

X-ray Absorption Fine Structure(XAFS), also called X-ray Absorption Spectro scopy (XAS), It is a powerful tool for studying the local atomic or electronic struct ure of materials based on synchrotron radiation light source, and is widely used in hot fields such as catalysis, energy and nano. 

X-ray Absorption Fine StructureXAFS


The XAFS spectrum consists of two main parts: X-ray absorption near-side structure (XANES) and extended X-ray absorption Fine structure (EXAFS).

EXAFS: The energy range is about 50eV to 1000eV behind the absorption edge, which comes from X-ray excitation

The inner layer of photoelectrons results from a single electron scattering effect between the surrounding atom and the absorbing atom.

XANES: A range of about 10eV before the absorption edge to about 50eV after the absorption edge, mainly from

X-rays.Multiple scattering of single electrons between surrounding and absorbing atoms by excited inner shell photoelectrons.

X-ray


Application field:

Industrial catalysis, energy storage materials, nanomaterials, environmental toxicology, also quality analysis, heavy element analysis, etc

X-ray Absorption Fine Structure