Products

Featured products

  • Diffractometer
    Diffractometer
    1. The accuracy of Diffractometer is high. 2. The application range of Diffractometer is wide. 3. Diffractometer is easy to operate, convenient and efficient.
    More
  • Single Crystal XRD
    Single Crystal XRD
    1.The single crystal machine adopts PLC control technology. 2.Modular design, accessories plug and play. 3.Electronic lead door interlocking equipment with double protection. 4.Single crystal X-ray tube: a variety of targets can be selected, such as Cu, Mo,etc. 5. Single crystal adopts four-circle concentric technology to ensure that the center of no goniometer remains unchanged.
    More
  • Series X-ray Crystal Analyzer
    Series X-ray Crystal Analyzer
    1. X-ray instrument is easy to operate and fast to detect. 2. X-ray instrument is accurate and reliable, with excellent performance. 3. X-ray instrument has various functional accessories to meet the needs of different testing purposes.
    More
  • Powder Diffractometer
    Powder Diffractometer
    1. Detector type: Array detector or SDD detector; 2. PLC automatic control calculus, Integration mode conversion, PLC automatically performs PHA, dead time correction 3.Sample measurement type: powder sample, liquid samples, melt-state samples, viscous samples, loose powders, bulk solid samples 4.Available with a variety of diffractometer accessories 5.Maximum output powder: 3kW
    More

Contact us

Lithium battery negative black spot cause analysis!

2023-10-25

1 Negative dark spot phenomenon

After using the LFP positive electrode and the graphite negative electrode in accordance with the conventional manufacturing process for the first time, it was found that the battery capacity was less than 0.1% to 0.5% of the normal level, and the battery thickness increased by 1.85%.

TD-3500 X-ray Diffractometer

2. Morphology & composition of negative dark spots

SEM&EDS composition analysis was performed on the black spot position at the end of the polar plate and the normal polar plate. The results showed that the composition of the normal negative electrode plate was 100%C element, and the black spot position also contained 4%-44% O element, 1%-3% F/P element, and 2% Na element at individual points (FIG. 3).

TD-3700 X-ray Diffractometer

3. Cause analysis of negative dark spots

The structure of negative carbon materials is complex and there are many kinds, and their conductive behavior varies with different electrolytic liquid systems. The chemical or electrochemical reaction of the electrolyte at the negative electrode interface has an important impact on the capacity characteristics and charge-discharge characteristics of the battery. Therefore, the failure analysis of the negative electrode surface should start from the structural characteristics of the carbon negative electrode material, the composition of the electrolytic liquid system, and the matching degree of the reaction between the negative electrode and the electrolyte interface. Moreover, the control of interface reaction and the improvement of battery performance have important guiding effect.


TD-3500 X-ray DiffractometerTD-3700 X-ray Diffractometer

     TD-3700 X-ray Diffractometer                                 TD-3500 X-ray Diffractometer